Built for the way your line actually runs.
A packaged drinking water plant with a copper contact / ionisation stage, inline copper concentration control and traceability, for brands selling copper (tamra) water.
Copper water sells on an Ayurvedic proposition, but it is regulated on a toxicological one — copper in packaged drinking water is capped by BIS, and an uncontrolled copper vessel infusion drifts well past that limit as contact time varies. This line replaces "store it in a copper pot" with a metered process: RO permeate passes through a controlled copper contactor, an inline analyser reads concentration, and dosing residence time is trimmed automatically. You get a consistent, defensible ppm value on every batch, plus the QC records to support it during a BIS surveillance audit.



Who this configuration suits.
Get a detailed quote for the Copper Water Plant.
Layout drawing, utility schedule, BIS / FSSAI checklist, itemised quotation in 24 hours.
Everything we ship with this plant.
Standard turnkey scope. Optional add-ons quoted on request.
Specs at a glance.
| Output | 60 BPM (3,600 BPH) |
| Copper concentration | Controlled within BIS permitted limit for packaged drinking water |
| Control method | Inline analyser + PLC residence-time trim |
| Bottle sizes | 500ml, 750ml, 1L PET or glass |
| Power load | 45–55 kW |
| Footprint | 3,000–4,000 sq.ft. |
| Manpower | 6–8 per shift |
| Compliance | BIS IS 14543 + documented batch copper records |
Price on Request.
Every plant is quoted against your capacity, feedwater analysis, plot and product mix. Send us those and you get an itemised proposal within 24 hours.
Output, degree of automation and whether you need redundancy on critical stations.
A high-TDS, iron-heavy or seasonal input changes the treatment train and its cost materially.
Machinery only, or turnkey with civil drawings, utilities, commissioning and BIS / FSSAI documentation.
Number of SKUs, bottle sizes and how fast you need to switch between them.
Common questions.
Is copper water allowed under BIS packaged drinking water rules?+
Copper is a permitted parameter with a maximum limit, not a banned one. The engineering requirement is that you stay inside that limit consistently, which is exactly what the inline analyser and trim control are for. We supply the QC record format your BIS auditor will ask for.
Why not just use copper vessels for storage?+
Because concentration then depends on contact time, surface area and temperature — all of which vary. That produces batches above and below your label claim. A metered contactor keeps the value inside a narrow, testable band.